CARLIN 60200FRS PRIMARY CONTROL

Item SKU - 60200FRS by Carlin
EDP - 1112457


Please Login for Pricing

Product Description

* FOR EZGAS BURNERS & CARLIN 201 GAS

Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas, EZ-Gas Pro

& 201GAS Burners. Now With LCD Screen!

***Important Note***

When Installing On A Covered Burner You Must Also Purchase The 33902FS Low

Profile Junction Box. It Is NOT Included With This Control.

Features:

On-Board LCD Screen

Easy to Understand Icons for Inputs and Outputs

Displays micro-amp Flame reading

Display operational information

_ Fault History records last 50 fault

cycles to aid the technician in

troubleshooting

_ Field Settable Timings

_ Pre-purge (0, 10, 30, 90)

_ Trial for Ignition Time (4, 6)

_ Post-Purge (0, 10, 15, 30, 60, 120)

_ Number of Recycles allowed (0, 1, 3)

_ Serviceman Reset Protection (3)

_ Low Voltage Terminals

TT (can be programmed as Used or Not used)

Blocked Vent input (contact closure, functions as a low voltage limit)

CO input (contact closure) required to start C.F.H ., lockout if not

detected during run

Alarm output (dry contacts) 24VAC/DC

Power input (red/white wire) 120 VAC, 60 HZ, 9 VA

Limit circuit input (black wire) 120 VAC, 60 HZ

Motor load (orange wire) 10 FLA / 60 LRA

(reduce by valve and ignition load)

Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA

Valve load (violet wire) 2 amps

Aux 120 VAC, 1 amp

Alarm contacts (dry contacts) 24V, AC/DC, 2A

Operating temperature limits +32xF to +140xF

Storage temperature limits -40xF to +185xF

Thermostat 24 VAC, 0.1A

Blocked Vent 12 VDC. 2mA

CO 12 VDC. 2mA

Agencies UL recognized (US & Canada)

Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S,

602002FR-363S

CARLIN 60200FRS PRIMARY CONTROL

Item SKU - 60200FRS by Carlin (EDP 1112457)

Stock / Price Information

Please Login for Pricing

Product Description

* FOR EZGAS BURNERS & CARLIN 201 GAS

Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas, EZ-Gas Pro

& 201GAS Burners. Now With LCD Screen!

***Important Note***

When Installing On A Covered Burner You Must Also Purchase The 33902FS Low

Profile Junction Box. It Is NOT Included With This Control.

Features:

On-Board LCD Screen

Easy to Understand Icons for Inputs and Outputs

Displays micro-amp Flame reading

Display operational information

_ Fault History records last 50 fault

cycles to aid the technician in

troubleshooting

_ Field Settable Timings

_ Pre-purge (0, 10, 30, 90)

_ Trial for Ignition Time (4, 6)

_ Post-Purge (0, 10, 15, 30, 60, 120)

_ Number of Recycles allowed (0, 1, 3)

_ Serviceman Reset Protection (3)

_ Low Voltage Terminals

TT (can be programmed as Used or Not used)

Blocked Vent input (contact closure, functions as a low voltage limit)

CO input (contact closure) required to start C.F.H ., lockout if not

detected during run

Alarm output (dry contacts) 24VAC/DC

Power input (red/white wire) 120 VAC, 60 HZ, 9 VA

Limit circuit input (black wire) 120 VAC, 60 HZ

Motor load (orange wire) 10 FLA / 60 LRA

(reduce by valve and ignition load)

Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA

Valve load (violet wire) 2 amps

Aux 120 VAC, 1 amp

Alarm contacts (dry contacts) 24V, AC/DC, 2A

Operating temperature limits +32xF to +140xF

Storage temperature limits -40xF to +185xF

Thermostat 24 VAC, 0.1A

Blocked Vent 12 VDC. 2mA

CO 12 VDC. 2mA

Agencies UL recognized (US & Canada)

Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S,

602002FR-363S