IBC HC 20-125 Natural Gas Wall Hung Condensing Boiler with Circulator

Item SKU - HC 20-125 by Test
EDP - 1085572


Please Login for Pricing

Product Description

20,000 BTU input to 125,000 BTU input - 18,600 BTU output to 110,800 BTU output - Can be converted to LP with optional LP kit

Single pass copper/aluminum heat exchanger - Built in outdoor reset control

Push button LED boiler control - 2 inch and 3 inch venting options - Includes 3/4 inch x 24 inch flexible condensate hose

Supply, return, and gas connections on bottom of the boiler - Exhaust and combustion air are on the top of the boiler

Specifications

These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).

Fuel Type
Natural Gas
Type
Water
Heat Exchanger Material
Copper/Aluminum
BTU Input
125000
BTU Output
110800
Annual Fuel Usage Efficiency (AFUE)
95
Domestic Hot Water
No
Vent Type
Direct Vent
Building Type
Residential
Length (inches)
11.1
Width (inches)
19.8
Height of Boiler (inches)
31.3
Vent Material
PVC/CPVC
Supply
Male Iron Pipe 1
Return
Male Iron Pipe 1
Gas Connection (inches)
1/2
Vent Size (inches)
3
Approximate Weight (pounds)
85

IBC HC 20-125 Natural Gas Wall Hung Condensing Boiler with Circulator

Item SKU - HC 20-125 by Test (EDP 1085572)

Stock / Price Information

Please Login for Pricing

Product Description

20,000 BTU input to 125,000 BTU input - 18,600 BTU output to 110,800 BTU output - Can be converted to LP with optional LP kit

Single pass copper/aluminum heat exchanger - Built in outdoor reset control

Push button LED boiler control - 2 inch and 3 inch venting options - Includes 3/4 inch x 24 inch flexible condensate hose

Supply, return, and gas connections on bottom of the boiler - Exhaust and combustion air are on the top of the boiler

Specifications

These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).

Fuel Type
Natural Gas
Type
Water
Heat Exchanger Material
Copper/Aluminum
BTU Input
125000
BTU Output
110800
Annual Fuel Usage Efficiency (AFUE)
95
Domestic Hot Water
No
Vent Type
Direct Vent
Building Type
Residential
Length (inches)
11.1
Width (inches)
19.8
Height of Boiler (inches)
31.3
Vent Material
PVC/CPVC
Supply
Male Iron Pipe 1
Return
Male Iron Pipe 1
Gas Connection (inches)
1/2
Vent Size (inches)
3
Approximate Weight (pounds)
85