Ruud RCF-2417STAVUA 2 Ton Vertical Uncased Furnace Coil
Item SKU - RCF2417STAVUA by Rheem / Ruud
EDP - 832731
Product Description
Overview
Ruud Indoor Furnace cased coils and replacement uncased coils are designed for use with Ruud outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow.
Features
- This coil is vertical only
- Can be used on gas or oil furnaces, but cannot be used on 14 wide oil furnaces and cannot be installed as horizontal left application on any oil furnace
- Coils are tested at the factory with an extensive refrigerant leak check
- Constructed of aluminum fins bonded to internally grooved aluminum tubing
- Copper sweat refrigerant connections
- Coils feature two sets of 3/4 inch condensate drain connections for ease of connection
- Unique drain pan design maximizes application flexibility and condensate removal
- Chatleff metering device connections at inlet and outlet of TXV and equalizer connection
- Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal set material
- Compatible with Germicidal UV Resistant Light System
- Bi-directional air flow eliminates the need to switch any internal components from horizontal left to right
Specifications
These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).
Type
Material
Refrigerant
Height (inches)
Width (inches)
Depth (inches)
Cased
BTU
Nominal Capacity (Tons)
Configuration
Inlet Size
Outlet Size
Rows
Approximate Weight (pounds)
Ruud RCF-2417STAVUA 2 Ton Vertical Uncased Furnace Coil
Item SKU - RCF2417STAVUA by Rheem / Ruud (EDP 832731)
Product Description
Overview
Ruud Indoor Furnace cased coils and replacement uncased coils are designed for use with Ruud outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow.
Features
- This coil is vertical only
- Can be used on gas or oil furnaces, but cannot be used on 14 wide oil furnaces and cannot be installed as horizontal left application on any oil furnace
- Coils are tested at the factory with an extensive refrigerant leak check
- Constructed of aluminum fins bonded to internally grooved aluminum tubing
- Copper sweat refrigerant connections
- Coils feature two sets of 3/4 inch condensate drain connections for ease of connection
- Unique drain pan design maximizes application flexibility and condensate removal
- Chatleff metering device connections at inlet and outlet of TXV and equalizer connection
- Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal set material
- Compatible with Germicidal UV Resistant Light System
- Bi-directional air flow eliminates the need to switch any internal components from horizontal left to right
Specifications
These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).
Type |
|
|
Material |
|
|
Refrigerant |
|
|
Height (inches) |
|
|
Width (inches) |
|
|
Depth (inches) |
|
|
Cased |
|
|
BTU |
|
|
Nominal Capacity (Tons) |
|
|
Configuration |
|
|
Inlet Size |
|
|
Outlet Size |
|
|
Rows |
|
|
Approximate Weight (pounds) |
|